Tune Intensity#

The Lidar generic wpm model can report raw or range-normalized intensity. Choose the convention, scale and optional lookup table to match the device’s output encoding. These controls change the intensity assigned to detected returns; they do not determine which returns are detected.

The Lidar generic core model intensity controls use different names, modes and scales.

Before you start. The controls are intensityProcessing, intensityMappingType, intensityScale and intensityMappingEncoding, all under omni:sensor:LidarWpm:. See USD Attributes and Sensor API Schemas for values and defaults. Range normalization depends on the selected return-processing mode.

Intensity encoding#

Intensity is a float32 channel encoded after detection. Encoding does not change peak selection, return counts, ordering or scan merging, and cannot recover rejected returns. Detection depends on the processing mode and thresholds defined in USD Attributes.

Accepted edits to the four intensity attributes preserve the scan and apply to detected returns at the next publication. See Retune the Sensor While It Runs.

Raw and range-normalized intensity#

intensityProcessing selects one of two conventions. Both end in the same presentation stage: a base intensity between 0 and 1 is passed through the mapping selected by intensityMappingType and multiplied by intensityScale.

raw:
    Intensity = intensityScale * map(clamp(rawDetectorIntensity, 0, 1))

rangeNormalized, intensityScale > 0:
    fraction = clamp(apparentReflectivity / intensityScale, 0, 1)
    Intensity = intensityScale * map(fraction)

With raw, base intensity is the detector’s normalized response, clamped to [0, 1]. The same surface generally produces a weaker response at a greater range.

With rangeNormalized (default), base intensity is apparent reflectivity divided by intensityScale. Apparent reflectivity is the reflectivity an ideal diffuse surface facing the sensor would need to produce the detected signal at that range, relative to the model’s reference signal.

Normalization removes the modeled range and calibration response. In waveform and directDetector modes it also removes aperture response, but retains detector noise. In directMaterial mode it removes range, gain and divergence factors while retaining detector angular response. Apparent reflectivity therefore depends on viewing angle, specularity and model calibration; it is not a vendor-independent measurement or the material’s reflectivity alone.

Surface response depends on its non-visual material labels (Non-Visual Sensor Materials). When omni:sensor:LidarWpm:useVisualMaterialInputs is on, the visual material is consulted as well; refer to USD Attributes.

Non-linear mapping#

intensityMappingType = linear (the default) applies no lookup-table adjustment to the base intensity.

nonlinear and nonlinearEncodingOnly use intensityMappingEncoding, a table of finite values. For each return, the selected entry has index floor(baseIntensity * (encodingCount - 1)), where encodingCount is the number of table entries.

The table length determines how the selected entry is used:

  • Fewer than intensityScale * 100 entries: add it to the base intensity.

  • At least intensityScale * 100 entries: replace the base intensity with it.

At the default scale, the threshold is 255 entries. The mapped value is then multiplied by intensityScale.

nonlinear and nonlinearEncodingOnly require a non-empty intensityMappingEncoding. An empty table (the default) rejects the whole parameter set; see Retune the Sensor While It Runs for rejection behavior. nonlinearDecodingOnly requires no table and acts like linear because this model has no decoding table.

Note

The base intensity is clamped to the unit range before the lookup; the entries of the table are not. Author the table so that the mapped value stays in the unit range: replacement entries between 0 and 1, correction entries small enough that base plus entry stays between 0 and 1. Every published value then lies between 0 and intensityScale, as it does with linear mapping.

Calculation example#

With linear mapping and the default scale of 2.55, apparent reflectivities of 8%, 10%, 100%, 180% and 255% are published as 0.08, 0.10, 1.0, 1.8 and 2.55. Values at or above 255% clamp to 2.55: the scale is the full scale, and, read as a fraction, the apparent reflectivity at which the value saturates. A scale of 1.0 publishes the apparent reflectivity itself, saturating at 100%. A zero scale publishes zero intensity for every return, in every mode.

Verification#

Read Intensity within Counts[0] and select entries with the VALID bit set in Flags. Check the following:

  • Every value lies between 0 and intensityScale.

  • Face two plates of the same material to the sensor at two different ranges, both far enough that neither reads the full scale in raw: a plate close to the sensor saturates the detector response and reads the full scale whatever its range. In rangeNormalized the two plates read about the same apparent reflectivity; in raw the farther plate reads smaller. If switching the convention leaves both values unchanged, check saturation and the update log; unchanged output alone does not establish that the edit was rejected.

  • Switch intensityProcessing while the sensor runs. The new encoding applies at the next publication. It changes intensity for the same detected returns, preserving their count and order. Consecutive publications can still have different detections because of scene motion, scan timing or noise; a changed count alone says nothing about whether the edit was accepted.

Potential issues#

  • Intensity saturates. Check the convention first, raw against rangeNormalized, then intensityScale, then omni:sensor:LidarWpm:calibrationGain, the detector field of view and the material assignment of the surfaces, before touching the detection thresholds: mapping cannot recover a signal the return pipeline already rejected, and a threshold edit changes which returns exist.

  • The values are on a different scale than the consumer expects. A consumer has to know which processing mode and scale were selected, because no separate Reflectivity channel is published; see the Intensity description in Outputs.

  • An intensity edit appears to do nothing. Either the table is not read, because only nonlinear and nonlinearEncodingOnly read intensityMappingEncoding, or the parameter set was refused: intensityScale must be finite and non-negative, every entry of intensityMappingEncoding must be finite, the values of intensityProcessing and intensityMappingType must be spelled exactly as the schema lists them, and nonlinear or nonlinearEncodingOnly needs a non-empty table. The reason is logged as an error; refer to Retune the Sensor While It Runs for what a refused set leaves in place and to Sensor Definition Validation.